top of page
ZYGOS_MARITIME_SERVICES-2.jpg

ZYGOS WORKSHOP

LOCATION

Greece 

What We Do

ZYGOS has managed to establish - since June 2023 - the first hydraulic test bench in Greece specialised in OH and calibration of FIVA/ELFI/ELVA Valves for Man Diesel & Turbo Electronically 2-stroke engines.

 

All FIVA/ELFI/ELVA are supported.

Scope of work for each FIVA/ELFI/ELVA Valve includes following items:
 
•⁠  ⁠Disasembly of multi-way valve
•⁠  ⁠Cleaning & Inspection of valve housing, main spool, pilot valve & sensor
•⁠  ⁠Seals Replacement (OH Kit supplied by Zygos, genuine spare parts used only)
•⁠  ⁠Testing of control/pilot valve
•⁠  ⁠Testing of feedback sensor
•⁠  ⁠Calibration of mechanical center of the spool & feedback sensor
•⁠  ⁠Function Test: exhaust valve open/close, fuel injector open/close, internal leakages check using test bench
•⁠  ⁠Final Work Report

 

Since June 2024, ZYGOS has managed to establish an additional test bench for HPS Pumps of Man Diesel & Turbo Electronically 2-stroke engines.
 
Either Gear or Motor Pumps can be OH at our workshop, and tested on our test bench using genuine spare parts only.

Parker and/or Rexroth Pumps are included in the list of pumps that can be tested on our equipment.

 

Scope of work includes:

  • Dismantling, Cleaning and Reassembling of the pump

  • Simulate engine running condition via control Proportional Valve during testing

  • Carry out pump testing up to 750 L/min capacity

  • Calibrate inductive sensor and safety check

  • Proportional Valve test

  • Final work Report & Graphic Display
     

The Workshop

Workshop has 260m2 total space & capacity and is based at Koropi Industrial Area.

 

All spare parts related to FIVA / ELFI / ELVA or HPS Pumps (OH Kits, Proportional Valves, Inductive Sensors, other major Components), even FIVA / ELFI / ELVA or HPS Pumps Assembly Units are available, to fulfil any routine or urgent request of our customers.

ZYGOS_MARITIME_SERVICES-8.jpg